Description
Features:
Counter and 7-segment decoding in one package
Easily interfaced with 7-segment display types
Fully static counter operation: DC to 6 MHz (typ.) at V
DD
= 10 V
Ideal for low-power displays
“Ripple blanking” and lamp test (CD4033B)
100% tested for quiescent current at 20 V
Standardized, symmetrical output characteristics
5-V, 10-V, and 15-V parametric ratings
Schmitt-triggered clock inputs
CD4033 Pinout
Pin No
Pin Name
Description
1
CLK 1
Clock Signal 1
2
CLK INHIBIT 1
Clock Inhibit Signal
3
R-BLANKING IN
Ripple Blanking Input
4
R BLANKING OUT
Ripple Blanking Output
5
C-OUT
Carry Out Signal
6
f
Output f of counter
7
g
Output g of counter
8
VSS
Source Supply Voltage
9
d
Output d of counter
10
a
Output a of counter
11
e
Output e of counter
12
b
Output b of counter
13
c
Output c of counter
14
L-TEST
Lamp Test Pint
15
Reset
Reset
16
VDD
Drain supply Voltage
Technical Specifications
Physical
Case/Package
PDIP
Contact Plating
Gold
Mount
Through Hole
Number of Pins
16
Technical
Clock Edge Trigger Type
Positive Edge
Direction
Unidirectional
Frequency
16 MHz
Logic Function
Counter
Max Operating Temperature
125 °C
Max Supply Voltage
18 V
Min Operating Temperature
-55 °C
Min Supply Voltage
3 V
Number of Bits
7
Number of Bits per Element
5
Number of Elements
1
Propagation Delay
600 ns
Quiescent Current
100 µA
Reset
Asynchronous
Sync/Async
Synchronous
Turn-On Delay Time
600 ns
Applications
Decade Counting 7 Segment Decimal Display
Frequency Division 7 Segment Decimal Displays
Clocks, Watches, Timers (e.g. ÷ 60, ÷ 60, ÷12 Counter/Display)
Counter/Display Driver For Meter Applications
CD4033 IC Datasheet

Reviews
There are no reviews yet.